Μετρητής ραδιενέργειας για ακτινοβολία Α, Β, Γ, και Χ
Features a three-second update and a Utility Menu that allows you to change the default settings for several operating parameters.
Its digital liquid crystal display (LCD) shows the current radiation level in your choice of SI units (microsieverts per hour) from .000 to 1,100 and counts per minute (CPM) from 0 to 350,000 or counts per second (CPS) from 0 to 3,500.
For users of conventional units mR/hr (milliroentgens per hour) from .000 to 110 and CPM are optional in the Utility Menu.
This instrument also offers an accumulated total and timer function, up to 9,999,000 counts and 40 hours.
Monitor personal radiation exposure
Monitor an area or perimeter
Detect radiation leaks and contamination
Ensure regulatory compliance
Monitor changes in background radiation
Demonstrate principles of nuclear physics
Check for radioactive minerals in the earth
Specifications
Sensor:
Halogen-quenched Geiger-Mueller detector (LND712)
Mica end window density is 1.5-2.0 mg/cm²
Side wall is 0.012″ #446 stainless steel
Detects Alpha, Beta, Gamma, and X-radiation
Display: 4-digit liquid crystal display with mode indicators
Accuracy: ±10% typical; ±15% max. (µSv/hr and mR/hr modes)
Alert: User-adjustable alert level to 500 µSv/hr and 60,000 CPM. Beeper sounds the alert
Anti-Saturation: Readout holds at full scale in fields up to 100 times the maximum ready
Audio: Beeper chirps for each count (can be muted)
Calibration: Cesium- 137 (gamma)
Certifications: CE Certified, RoHS Compliant, Meets WEEE standards, and ISO 9001:2001 & ISO 14001
Count Light: Red LED flashes with each count
Detector:
Halogen-quenched Geiger-Mueller detector (LND712)
Mica end window density is 1.5-2.0 mg/cm²
Side wall is 0.012″ #446 stainless steel
Detects Alpha, Beta, Gamma, and X-radiation
Gamma Sensitivity: 1,000 CPM/mR/hr referenced to Cs-137
Operating Range:
mR/hr: .000-110 |
CPM: 0-350,000 |
µSv/hr: .000-1,100 |
CPS: 0-3,500 |
Total: 0-9,999,000 counts |
Timer: up to 40 hours |
Options: Computer software and cable available
Ports:
Output: Stereo 3.5 mm jack sends counts to computers, data loggers, other CMOS-compatible devices, headphones and educational data collection systems.
Input: Mono 2.5 mm jack provides electronic calibration input. 0-3.3 V, >5 µs width, rising edge triggered.
Power: One 9-volt alkaline battery; average battery life is 2,000 hours at typical, 700 hours minimum at normal background radiation levels at sea level. Battery life decreases as radiation level rises.
Sensitivity: 1000 cpm/mR/hr referenced to Cs-137
Size: 150 x 80 x 30 mm (5.9″ x 3.2″ x 1.2″)
Weight: 225 grams (8 oz) including battery